Energy saving refrigeration solution supplier since 2004.                                                                                                                                                                                                                                                                                                   

Language

Small air-cooled flake ice machine

2021/12/31

Small air-cooled flake ice machine

The standard power supply of small air-cooled flake ice machine is 380V/3P/50Hz. The power system can be changed according to the actual situation, but it must be noted when ordering. Adopting Danfoss and Tecumseh fully enclosed piston compressors, air-cooled condensers, and the overall form, the site can be put into operation only by providing water source and power supply. Flake ice machine

Technical parameter table of small air-cooled flake ice machine

Model

--

Ice production

Ton/D

Refrigerant

--

Running power consumption

Kw< /p>

Installation power

Kw

Operating weight

Kg

Dimensions

mm

F-FA-0.5

0.5

R22/R404A

2.1

2.5

196

1200×735×598

F-FA-0.75

0.75

R22/R404A

2.52

3

210

1200×735×648

F-FA-1.0

1.0

R22/R404A

3.9

4.5

245

1200×735×782

p>

F-FA-1.2

1.2

R22/R404A

4.3

5

280

1400×980×782

F-FA-1.6

1.6

R22/R404A

5.2

6

425

1560×1200×880

F-FA-2.0

2.0

R22/R404A

6.45

8

500

1560×1200×957

F-FA-2.5

2.5

R22/R404A

7.25

9

585

1590×1200×1017

F-FA-3.0

3.0

R22/R404A

10.5

11

645

1590×1200×1017

Note: The above data is based on dry bulb temperature 33℃, wet bulb temperature 22 ℃, inlet water temperature 25℃ working condition