The quality of the laboratory snowflake ice machine during installation is directly related to its later use. The less serious only affects the observation effect, and the more serious one will shorten the life of the laboratory snowflake ice machine. . Therefore, you must follow the prescribed steps when installing, and remember not to install and use blindly.
The use of laboratory snowflake ice maker points: 1. The laboratory snowflake ice maker should be installed in a place far away from the heat source, without direct sunlight, and well ventilated, and the ambient temperature should not exceed Celsius. 35 degrees, in order to prevent the excessively high ambient temperature from causing poor heat dissipation of the condenser and affecting the ice making effect. At the same time, be careful not to place it in a northern room or a ventilated place in the north, to prevent the temperature in the north from being too low in winter, resulting in no ice production. Generally, the temperature of ice production is controlled above 7 degrees, so when the ambient temperature is below 7 degrees, no If the ice is produced, the display is full and the prompt is full. Please don't be nervous. If there is no problem, it is a normal phenomenon. The ground on which the ice maker is installed should be solid and level. 2. The gap between the back and the left and right sides of the laboratory snowflake ice maker is not less than 30cm, and the top gap is not less than 60cm to ensure that the heat transfer of the machine is relatively good. 3. The ice maker should use an independent power supply, dedicated line power supply, equipped with fuse and leakage protection switch, and reliable grounding. 4. The water used in the laboratory snowflake cbfi ice machine must meet the national drinking water standards, and a water filter device should be installed to filter impurities in the water to avoid clogging the water pipe and polluting the water tank and ice mold. And affect the ice making performance. 5. Turn off the power when cleaning the laboratory snowflake ice maker. It is strictly forbidden to directly flush the body with a water pipe. Use neutral detergent for scrubbing. It is strictly forbidden to clean with acidic, alkaline and other corrosive solvents. 6. u200bu200bThe laboratory snowflake ice maker must unscrew the water inlet hose head for two months to clean the water inlet valve filter to prevent the sand and mud impurities in the water from blocking the water inlet, which will cause the water inlet to become small and cause no ice production. 7. The laboratory snowflake ice maker must clean the surface of the condenser every two months. Poor condensation and heat dissipation will cause damage to the compressor components. When cleaning, use a vacuum cleaner, a small brush, etc. to clean the oil and dust on the condensing surface. Do not use sharp metal tools to clean, so as not to damage the condenser.Copyright © 2025 Guangzhou Icesource Co., Ltd. - www.icesourcegroup.com All Rights Reserved. 粤ICP备17010012号